Results 1 - 20 de 16.706
Filter
1.
ACS Sens ; 9(4): 2183-2193, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38588327

ABSTRACT

Sensitive and selective acetone detection is of great significance in the fields of environmental protection, industrial production, and individual health monitoring from exhaled breath. To achieve this goal, bimetallic Au@Pt core-shell nanospheres (BNSs) functionalized-electrospun ZnFe2O4 nanofibers (ZFO NFs) are prepared in this work. Compared to pure NFs-650 analogue, the ZFO NFs/BNSs-2 sensor exhibits a stronger mean response (3.32 vs 1.84), quicker response/recovery speeds (33 s/28 s vs 54 s/42 s), and lower operating temperature (188 vs 273 °C) toward 0.5 ppm acetone. Note that an experimental detection limit of 30 ppb is achieved, which ranks among the best cases reported thus far. Besides the demonstrated excellent repeatability, humidity-enhanced response, and long-term stability, the selectivity toward acetone is remarkably improved after BNSs functionalization. Through material characterizations and DFT calculations, all these improvements could be attributed to the boosted oxygen vacancies and abundant Schottky junctions between ZFO NFs and BNSs, and the synergistic catalytic effect of BNSs. This work offers an alternative strategy to realize selective subppm acetone under high-humidity conditions catering for the future requirements of noninvasive breath diabetes diagnosis in the field of individual healthcare.


Subject(s)
Acetone , Breath Tests , Gold , Nanofibers , Nanospheres , Platinum , Acetone/analysis , Acetone/chemistry , Nanofibers/chemistry , Gold/chemistry , Breath Tests/methods , Nanospheres/chemistry , Platinum/chemistry , Humans , Limit of Detection , Oxygen/chemistry , Electrochemical Techniques/methods
2.
BMC Gastroenterol ; 24(1): 143, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38654193

ABSTRACT

BACKGROUND: Food malabsorption and intolerance is implicated in gastrointestinal symptoms among patients with irritable bowel syndrome (IBS). Key triggers include fructose and fructan. Prior studies examined fructose and fructan malabsorption separately in IBS patients. None have concurrently assessed both within the same patient group. We aimed to investigate the association between fructose and fructan malabsorption in the same patients with IBS using hydrogen breath testing (HBT). METHODS: We retrospectively identified patients with IBS who underwent fructose and fructan HBTs and abstracted their results from the electronic medical record. Fructose and fructan HBTs were performed by administering a 25 g fructose solution or 10 g fructan solution, followed by breath hydrogen readings every 30 min for 3 h. Patients were positive for fructose or fructan malabsorption if breath hydrogen levels exceeded 20 ppm. RESULTS: Of 186 IBS patients, 71 (38.2%) were positive for fructose malabsorption and 91 (48.9%) were positive for fructan malabsorption. Of these patients, 42 (22.6%) were positive for fructose malabsorption and fructan malabsorption. Positive fructose HBT readings were significantly associated with positive fructan HBT readings (p = 0.0283). Patients positive for fructose malabsorption or fructan malabsorption had 1.951 times higher odds of testing positive for the other carbohydrate. CONCLUSIONS: Our results reveal a clinically significant association between fructose malabsorption and fructan malabsorption in patients with IBS. Fructan malabsorption should be assessed in patients with fructose malabsorption, and vice versa. Further studies are required to identify the mechanisms underlying our findings.


Subject(s)
Breath Tests , Fructans , Fructose , Irritable Bowel Syndrome , Malabsorption Syndromes , Humans , Irritable Bowel Syndrome/metabolism , Irritable Bowel Syndrome/complications , Fructose/metabolism , Female , Male , Retrospective Studies , Malabsorption Syndromes/metabolism , Malabsorption Syndromes/etiology , Malabsorption Syndromes/complications , Fructans/metabolism , Adult , Middle Aged , Hydrogen/analysis , Hydrogen/metabolism
3.
Arch Med Sadowej Kryminol ; 73(4): 308-324, 2024.
Article in English, Polish | MEDLINE | ID: mdl-38662483

ABSTRACT

The aim of the study was to determine the components of measurement uncertainty in the concentration of alcohol in exhaled breath and to determine the state of sobriety at the time of incident. Based on the literature review and the authors' experience in providing opinions for law enforcement and the judiciary, the influence of various factors on the final interpretation of sobriety state is described on the basis of measurement uncertainty of breath analyzers, uncertainty of retrospective and prospective calculations, and uncertainty related to the conversion of alcohol concentrations detected during breath and blood tests. The paper pays particular attention to interpreting the concentrations of ethanol in exhaled breath close to the legal limits of the state of sobriety and the state after alcohol use, or the state after alcohol use and the state of insobriety. Analyzing the results of an exhaled breath test concerning concentrations close to the values of 0.1 mg/dm3 and 0.25 mg/dm3, it is necessary to take into account the factors affecting the measurements obtained, including the measurement uncertainty of the determination of alcohol in exhaled breath, the processes of absorption, distribution and metabolism of ethyl alcohol, and the possibility of the presence of alcohol lingering in the oral cavity. The incorrect execution of measurements of the tested person's alcohol concentration is also a problematic issue. When determining sobriety state by means of retrospective and prospective calculations, it is important to remember that the uncertainty of the result is affected by a number of factors and depends, among other things, on the information provided by the suspect. Hence, the expert should draw conclusions particularly cautiously and any overestimation or underestimation of the components of uncertainty can lead to erroneous conclusions. Awareness of the uncertainties inherent in the results of a sobriety test or alcohol calculation allows for meaningful interpretation of test results and determination of the sobriety state of the person tested.


Subject(s)
Breath Tests , Ethanol , Humans , Breath Tests/methods , Ethanol/analysis , Driving Under the Influence/legislation & jurisprudence , Alcoholic Intoxication , Substance Abuse Detection/methods , Uncertainty , Exhalation , Alcohol Drinking
4.
J Extracell Vesicles ; 13(4): e12440, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38659349

ABSTRACT

Lung diseases, including lung cancer, are rising causes of global mortality. Despite novel imaging technologies and the development of biomarker assays, the detection of lung cancer remains a significant challenge. However, the lung communicates directly with the external environment and releases aerosolized droplets during normal tidal respiration, which can be collected, stored and analzsed as exhaled breath condensate (EBC). A few studies have suggested that EBC contains extracellular vesicles (EVs) whose microRNA (miRNA) cargos may be useful for evaluating different lung conditions, but the cellular origin of these EVs remains unknown. In this study, we used nanoparticle tracking, transmission electron microscopy, Western blot analyses and super resolution nanoimaging (ONi) to detect and validate the identity of exhaled EVs (exh-EVs). Using our customizable antibody-purification assay, EV-CATCHER, we initially determined that exh-EVs can be selectively enriched from EBC using antibodies against three tetraspanins (CD9, CD63 and CD81). Using ONi we also revealed that some exh-EVs harbour lung-specific proteins expressed in bronchiolar Clara cells (Clara Cell Secretory Protein [CCSP]) and Alveolar Type II cells (Surfactant protein C [SFTPC]). When conducting miRNA next generation sequencing (NGS) of airway samples collected at five different anatomic levels (i.e., mouth rinse, mouth wash, bronchial brush, bronchoalveolar lavage [BAL] and EBC) from 18 subjects, we determined that miRNA profiles of exh-EVs clustered closely to those of BAL EVs but not to those of other airway samples. When comparing the miRNA profiles of EVs purified from matched BAL and EBC samples with our three tetraspanins EV-CATCHER assay, we captured significant miRNA expression differences associated with smoking, asthma and lung tumor status of our subjects, which were also reproducibly detected in EVs selectively purified with our anti-CCSP/SFTPC EV-CATCHER assay from the same samples, but that confirmed their lung tissue origin. Our findings underscore that enriching exh-EV subpopulations from EBC allows non-invasive sampling of EVs produced by lung tissues.


Subject(s)
Breath Tests , Extracellular Vesicles , Lung , MicroRNAs , Humans , MicroRNAs/metabolism , MicroRNAs/genetics , Extracellular Vesicles/metabolism , Lung/metabolism , Breath Tests/methods , Female , Male , Exhalation , Middle Aged , Lung Neoplasms/metabolism , Lung Neoplasms/genetics , Biomarkers/metabolism , Adult
5.
BMC Pulm Med ; 24(1): 178, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622520

ABSTRACT

BACKGROUND: Asthma is a common disease characterized by chronic inflammation of the lower airways, bronchial hyperactivity, and (reversible) airway obstruction. The Global Initiative of Asthma Guideline recommends a flowchart to diagnose asthma with first-step spirometry with reversibility and a bronchial challenge test (BPT) with histamine or methacholine as a second step [1]. The BPT is considered burdensome, time-consuming for patients and staff, can cause side effects, and is expensive. In addition, this test strongly encumbers lung function capacity. Elevated Nitric Oxide (NO) is associated with airway eosinophilic inflammation in asthma patients and can be measured in exhaled air with the Fractional exhaled (Fe) NO-test. This low-burden FeNO-test could be used as an 'add-on' test in asthma diagnostics [2, 3]. METHODS AND ANALYSIS: This multi-center prospective study (Trial number: NCT06230458) compares the 'standard asthma diagnostic work-up' (spirometry with reversibility and BPT) to the 'new asthma diagnostics work-up' (FeNO-test as an intermediate step between the spirometry with reversibility and the BPT), intending to determine the impact of the FeNO-based strategy, in terms of the number of avoided BPTs, cost-effectiveness and reduced burden to the patient and health care. The cost reduction of incorporating the FeNO-test in the new diagnostic algorithm will be established by the number of theoretically avoided BPT. The decrease in burden will be studied by calculating differences in the Visual Analogue Scale (VAS) -score and Asthma Quality of Life Questionnaire (AQLQ) -score after the BPT and FeNO-test with an independent T-test. The accuracy of the FeNO-test will be calculated by comparing the FeNO-test outcomes to the (gold standard) BPTs outcomes in terms of sensitivity and specificity. The intention is to include 171 patients. ETHICS AND DISSEMINATION: The local medical ethics committee approved the proposed study and is considered a low-burden and risk-low study. The local medical ethics committee registration number: R23.005. STRENGTHS AND LIMITATIONS OF THIS STUDY: Strengths: This is the first study that investigates the value of the FeNO-test (cut off ≥ 50 ppb) as an add-on test, to determine the impact of the FeNO-based strategy, in terms of the number of avoided BPTs, cost-effectiveness, and reduced burden on the patient and health care. LIMITATIONS: High FeNO levels may also be observed in other diseases such as eosinophilic chronic bronchitis and allergic rhinitis. The FeNO-test can be used to rule in a diagnosis of asthma with confidence, however, due to the poor sensitivity it is not suitable to rule out asthma.


Subject(s)
Asthma , Bronchitis, Chronic , Humans , Fractional Exhaled Nitric Oxide Testing , Prospective Studies , Quality of Life , Breath Tests , Asthma/drug therapy , Nitric Oxide , Inflammation , Multicenter Studies as Topic
6.
Sci Rep ; 14(1): 8731, 2024 04 16.
Article in English | MEDLINE | ID: mdl-38627587

ABSTRACT

Early diagnosis of lung cancer (LC) can significantly reduce its mortality rate. Considering the limitations of the high false positive rate and reliance on radiologists' experience in computed tomography (CT)-based diagnosis, a multi-modal early LC screening model that combines radiology with other non-invasive, rapid detection methods is warranted. A high-resolution, multi-modal, and low-differentiation LC screening strategy named ensemble text and breath analysis (ETBA) is proposed that ensembles radiology report text analysis and breath analysis. In total, 231 samples (140 LC patients and 91 benign lesions [BL] patients) were screened using proton transfer reaction-time of flight-mass spectrometry and CT screening. Participants were randomly assigned to a training set and a validation set (4:1) with stratification. The report section of the radiology reports was used to train a text analysis (TA) model with a natural language processing algorithm. Twenty-two volatile organic compounds (VOCs) in the exhaled breath and the prediction results of the TA model were used as predictors to develop the ETBA model using an extreme gradient boosting algorithm. A breath analysis model was developed based on the 22 VOCs. The BA and TA models were compared with the ETBA model. The ETBA model achieved a sensitivity of 94.3%, a specificity of 77.3%, and an accuracy of 87.7% with the validation set. The radiologist diagnosis performance with the validation set had a sensitivity of 74.3%, a specificity of 59.1%, and an accuracy of 68.1%. High sensitivity and specificity were obtained by the ETBA model compared with radiologist diagnosis. The ETBA model has the potential to provide sensitivity and specificity in CT screening of LC. This approach is rapid, non-invasive, multi-dimensional, and accurate for LC and BL diagnosis.


Subject(s)
Lung Neoplasms , Volatile Organic Compounds , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Retrospective Studies , Sensitivity and Specificity , Volatile Organic Compounds/analysis , Algorithms , Breath Tests/methods
7.
J Breath Res ; 18(3)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38631337

ABSTRACT

The annual Breath Biopsy Conference hosted by Owlstone Medical gathers together the leading experts, early career researchers, and physicians working with breath as a biomarker platform for clinical purposes. The current topics in breath research are discussed and presented, and an overarching topical theme is identified and discussed as part of an expert panel to close the conference. The profiling of normal breath composition and the establishment of standards for analyzing breath compared to background signal were two important topics that were major focuses of this conference, as well as important innovative progress that has been made since last year, including the development of a non-invasive breath test for lung cancer and liver disease. This meeting report offers an overview of the key take-home messages from the various presentations, posters, and discussions from the conference.


Subject(s)
Biomarkers , Breath Tests , Humans , Breath Tests/methods , Biomarkers/analysis , Biopsy , Congresses as Topic , Lung Neoplasms/diagnosis
8.
Sensors (Basel) ; 24(7)2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38610554

ABSTRACT

Screening methods available for colorectal cancer (CRC) to date are burdened by poor reliability and low patient adherence and compliance. An altered pattern of volatile organic compounds (VOCs) in exhaled breath has been proposed as a non-invasive potential diagnostic tool for distinguishing CRC patients from healthy controls (HC). The aim of this study was to evaluate the reliability of an innovative portable device containing a micro-gas chromatograph in enabling rapid, on-site CRC diagnosis through analysis of patients' exhaled breath. In this prospective trial, breath samples were collected in a tertiary referral center of colorectal surgery, and analysis of the chromatograms was performed by the Biomedical Engineering Department. The breath of patients with CRC and HC was collected into Tedlar bags through a Nafion filter and mouthpiece with a one-way valve. The breath samples were analyzed by an automated portable gas chromatography device. Relevant volatile biomarkers and discriminant chromatographic peaks were identified through machine learning, linear discriminant analysis and principal component analysis. A total of 68 subjects, 36 patients affected by histologically proven CRC with no evidence of metastases and 32 HC with negative colonoscopies, were enrolled. After testing a training set (18 CRC and 18 HC) and a testing set (18 CRC and 14 HC), an overall specificity of 87.5%, sensitivity of 94.4% and accuracy of 91.2% in identifying CRC patients was found based on three VOCs. Breath biopsy may represent a promising non-invasive method of discriminating CRC patients from HC.


Subject(s)
Breath Tests , Colorectal Neoplasms , Humans , Preliminary Data , Prospective Studies , Reproducibility of Results , Colorectal Neoplasms/diagnosis
9.
World J Gastroenterol ; 30(6): 579-598, 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38463019

ABSTRACT

BACKGROUND: Helicobacter pylori (H. pylori) infection has been well-established as a significant risk factor for several gastrointestinal disorders. The urea breath test (UBT) has emerged as a leading non-invasive method for detecting H. pylori. Despite numerous studies confirming its substantial accuracy, the reliability of UBT results is often compromised by inherent limitations. These findings underscore the need for a rigorous statistical synthesis to clarify and reconcile the diagnostic accuracy of the UBT for the diagnosis of H. pylori infection. AIM: To determine and compare the diagnostic accuracy of 13C-UBT and 14C-UBT for H. pylori infection in adult patients with dyspepsia. METHODS: We conducted an independent search of the PubMed/MEDLINE, EMBASE, and Cochrane Central databases until April 2022. Our search included diagnostic accuracy studies that evaluated at least one of the index tests (13C-UBT or 14C-UBT) against a reference standard. We used the QUADAS-2 tool to assess the methodological quality of the studies. We utilized the bivariate random-effects model to calculate sensitivity, specificity, positive and negative test likelihood ratios (LR+ and LR-), as well as the diagnostic odds ratio (DOR), and their 95% confidence intervals. We conducted subgroup analyses based on urea dosing, time after urea administration, and assessment technique. To investigate a possible threshold effect, we conducted Spearman correlation analysis, and we generated summary receiver operating characteristic (SROC) curves to assess heterogeneity. Finally, we visually inspected a funnel plot and used Egger's test to evaluate publication bias. RESULTS: The titles and abstracts of 4621 studies were screened; 79 articles were retrieved and selected for full-text reading. Finally, 60 studies were included in the diagnostic test accuracy meta-analysis. Our analysis demonstrates superior diagnostic accuracy of 13C-UBT over 14C-UBT, indicated by higher sensitivity (96.60% vs 96.15%), specificity (96.93% vs 89.84%), likelihood ratios (LR+ 22.00 vs 10.10; LR- 0.05 vs 0.06), and area under the curve (AUC; 0.979 vs 0.968). Notably, 13C-UBT's DOR (586.47) significantly outperforms 14C-UBT (DOR 226.50), making it the preferred diagnostic tool for dyspeptic individuals with H. pylori infection. Correlation analysis revealed no threshold effect (13C-UBT: r = 0.48; 14C-UBT: r = -0.01), and SROC curves showed consistent accuracy. Both 13C-UBT and 14C-UBT showed high AUC values (13C-UBT 0.979; 14C-UBT 0.968) near 1.00, reinforcing their excellent accuracy and endorsing both as reliable diagnostic tools in clinical practice. CONCLUSION: In summary, our study has demonstrated that 13C-UBT has been found to outperform the 14C-UBT, making it the preferred diagnostic approach. Additionally, our results emphasize the significance of carefully considering urea dosage, assessment timing, and measurement techniques for both tests to enhance diagnostic precision. Nevertheless, it is crucial for researchers and clinicians to evaluate the strengths and limitations of our findings before implementing them in practice.


Subject(s)
Helicobacter Infections , Helicobacter pylori , Adult , Humans , Helicobacter Infections/diagnosis , Urea , Reproducibility of Results , Sensitivity and Specificity , Breath Tests/methods , Diagnostic Tests, Routine
10.
Biol Pharm Bull ; 47(4): 856-860, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38538325

ABSTRACT

The C3 carbon of glucose molecules becomes the C1 carbon of pyruvate molecules during glycolysis, and the C1 and C2 carbons of glucose molecules are metabolized in the tricarboxylic acid (TCA) cycle. Utilizing this position-dependent metabolism of C atoms in glucose molecules, [1-13C], [2-13C], and [3-13C]glucose breath tests are used to evaluate glucose metabolism. However, the effects of chronic ethanol consumption remain incompletely understood. Therefore, we evaluated glucose metabolism in ethanol-fed rats using [1-13C], [2-13C], and [3-13C]glucose breath tests. Ethanol-fed (ERs) and control rats (CRs) (n = 8 each) were used in this study, and ERs were prepared by replacing drinking water with a 16% ethanol solution. We administered 100 mg/kg of [1-13C], [2-13C], or [3-13C]glucose to rats and collected expired air (at 10-min intervals for 180 min). We compared the 13CO2 levels (Δ13CO2, ‰) of breath measured by IR isotope ratio spectrometry and area under the curve (AUC) values of the 13CO2 levels-time curve between ERs and CRs. 13CO2 levels and AUCs after administration of [1-13C]glucose and [2-13C]glucose were lower in ERs than in CRs. Conversely, the AUC for the [3-13C]glucose breath test showed no significant differences between ERs and CRs, although 13CO2 levels during the 110-120 min interval were significantly high in ERs. These findings indicate that chronic ethanol consumption diminishes glucose oxidation without concomitantly reducing glycolysis. Our study demonstrates the utility of 13C-labeled glucose breath tests as noninvasive and repeatable methods for evaluating glucose metabolism in various subjects, including those with alcoholism or diabetes.


Subject(s)
Carbon Dioxide , Glucose , Humans , Rats , Animals , Glucose/metabolism , Carbon Dioxide/analysis , Carbon Dioxide/metabolism , Carbon Isotopes/analysis , Breath Tests/methods , Ethanol , Pyruvic Acid
11.
Spectrochim Acta A Mol Biomol Spectrosc ; 314: 124181, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38527410

ABSTRACT

Distinct diagnosis between Lung cancer (LC) and gastric cancer (GC) according to the same biomarkers (e.g. aldehydes) in exhaled breath based on surface-enhanced Raman spectroscopy (SERS) remains a challenge in current studies. Here, an accurate diagnosis of LC and GC is demonstrated, using artificial intelligence technologies (AI) based on SERS spectrum of exhaled breath in plasmonic metal organic frameworks nanoparticle (PMN) film. In the PMN film with optimal structure parameters, 1780 SERS spectra are collected, in which 940 spectra come from healthy people (n = 49), another 440 come from LC patients (n = 22) and the rest 400 come from GC patients (n = 8). The SERS spectra are trained through artificial neural network (ANN) model with the deep learning (DL) algorithm, and the result exhibits a good identification accuracy of LC and GC with an accuracy over 89 %. Furthermore, combined with information of SERS peaks, the data mining in ANN model is successfully employed to explore the subtle compositional difference in exhaled breath from healthy people (H) and L/GC patients. This work achieves excellent noninvasive diagnosis of multiple cancer diseases in breath analysis and provides a new avenue to explore the feature of disease based on SERS spectrum.


Subject(s)
Lung Neoplasms , Stomach Neoplasms , Humans , Stomach Neoplasms/diagnosis , Artificial Intelligence , Lung Neoplasms/diagnosis , Spectrum Analysis, Raman , Breath Tests/methods , Lung
12.
Int Arch Occup Environ Health ; 97(4): 387-400, 2024 May.
Article in English | MEDLINE | ID: mdl-38504030

ABSTRACT

OBJECTIVE: In this pilot study on subway workers, we explored the relationships between particle exposure and oxidative stress biomarkers in exhaled breath condensate (EBC) and urine to identify the most relevant biomarkers for a large-scale study in this field. METHODS: We constructed a comprehensive occupational exposure assessment among subway workers in three distinct jobs over 10 working days, measuring daily concentrations of particulate matter (PM), their metal content and oxidative potential (OP). Individual pre- and post-shift EBC and urine samples were collected daily. Three oxidative stress biomarkers were measured in these matrices: malondialdehyde (MDA), 8-hydroxy-2'deoxyguanosine (8-OHdG) and 8-isoprostane. The association between each effect biomarker and exposure variables was estimated by multivariable multilevel mixed-effect models with and without lag times. RESULTS: The OP was positively associated with Fe and Mn, but not associated with any effect biomarkers. Concentration changes of effect biomarkers in EBC and urine were associated with transition metals in PM (Cu and Zn) and furthermore with specific metals in EBC (Ba, Co, Cr and Mn) and in urine (Ba, Cu, Co, Mo, Ni, Ti and Zn). The direction of these associations was both metal- and time-dependent. Associations between Cu or Zn and MDAEBC generally reached statistical significance after a delayed time of 12 or 24 h after exposure. Changes in metal concentrations in EBC and urine were associated with MDA and 8-OHdG concentrations the same day. CONCLUSION: Associations between MDA in both EBC and urine gave opposite response for subway particles containing Zn versus Cu. This diverting Zn and Cu pattern was also observed for 8-OHdG and urinary concentrations of these two metals. Overall, MDA and 8-OHdG responses were sensitive for same-day metal exposures in both matrices. We recommend MDA and 8-OHdG in large field studies to account for oxidative stress originating from metals in inhaled particulate matter.


Subject(s)
Railroads , Humans , Prospective Studies , Pilot Projects , Particulate Matter/analysis , Metals , Biomarkers/urine , Oxidative Stress , Breath Tests
13.
Lung Cancer ; 190: 107514, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38447302

ABSTRACT

INTRODUCTION: Breath analysis using a chemical sensor array combined with machine learning algorithms may be applicable for detecting and screening lung cancer. In this study, we examined whether perioperative breath analysis can predict the presence of lung cancer using a Membrane-type Surface stress Sensor (MSS) array and machine learning. METHODS: Patients who underwent lung cancer surgery at an academic medical center, Japan, between November 2018 and November 2019 were included. Exhaled breaths were collected just before surgery and about one month after surgery, and analyzed using an MSS array. The array had 12 channels with various receptor materials and provided 12 waveforms from a single exhaled breath sample. Boxplots of the perioperative changes in the expiratory waveforms of each channel were generated and Mann-Whitney U test were performed. An optimal lung cancer prediction model was created and validated using machine learning. RESULTS: Sixty-six patients were enrolled of whom 57 were included in the analysis. Through the comprehensive analysis of the entire dataset, a prototype model for predicting lung cancer was created from the combination of array five channels. The optimal accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 0.809, 0.830, 0.807, 0.806, and 0.812, respectively. CONCLUSION: Breath analysis with MSS and machine learning with careful control of both samples and measurement conditions provided a lung cancer prediction model, demonstrating its capacity for non-invasive screening of lung cancer.


Subject(s)
Lung Neoplasms , Volatile Organic Compounds , Humans , Lung Neoplasms/diagnosis , Lung Neoplasms/surgery , Exhalation , Predictive Value of Tests , Breath Tests , Early Detection of Cancer , Volatile Organic Compounds/analysis
14.
Hematology ; 29(1): 2335420, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38546338

ABSTRACT

OBJECTIVES: Thrombotic thrombocytopenic purpura (TTP) is a rare but life-threatening hematological disorder. Early differentiation between TTP and primary immune thrombocytopenia (ITP) accompanied by anemia is crucial to initiate an appropriate therapeutic strategy. The objective of this study was to evaluate the predictive value of red blood cell lifespan (RBCLS), determined using the carbon monoxide breath test, in the differential diagnosis of these two diseases. METHODS: We conducted a retrospective analysis of 23 patients with TTP and 32 patients with ITP accompanied by anemia. RBCLS measurements were compared and evaluated between these two patient groups. RESULTS: TTP patients had a significantly shorter mean RBCLS (20 ± 8 days) than patients with ITP accompanied by anemia (77 ± 22 days, P < 0.001) and healthy controls (114 ± 25 days, P < 0.001). In TTP patients, RBCLS showed a significant negative correlation with reticulocyte percentage and lactic dehydrogenase levels (P < 0.001). When using a standard baseline of 75 days, RBCLS demonstrated a sensitivity of 100% and specificity of 53.1% in identifying TTP. The diagnostic accuracy could reach 93% by excluding the impact of gastrointestinal bleeding. By employing the Receiver Operator Characteristics (ROC) curve, the area under the curve for RBCLS was 0.985 (95% CI: 0-1, P < 0.01) in predicting TTP, with an optimal cut-off value of 32 days, and sensitivity and specificity of 95.7% and 96.9%, respectively. CONCLUSIONS: Our study proposes a simple and accessible method for evaluating RBCLS to differentiate between TTP and ITP accompanied by anemia.


Subject(s)
Anemia , Purpura, Thrombocytopenic, Idiopathic , Purpura, Thrombotic Thrombocytopenic , Humans , Carbon Monoxide , Purpura, Thrombocytopenic, Idiopathic/complications , Purpura, Thrombocytopenic, Idiopathic/diagnosis , Purpura, Thrombotic Thrombocytopenic/complications , Purpura, Thrombotic Thrombocytopenic/diagnosis , Retrospective Studies , Breath Tests
15.
J Breath Res ; 18(2)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38502958

ABSTRACT

Clostridioides difficileinfection (CDI) is the leading cause of hospital-acquired infective diarrhea. Current methods for diagnosing CDI have limitations; enzyme immunoassays for toxin have low sensitivity andClostridioides difficilepolymerase chain reaction cannot differentiate infection from colonization. An ideal diagnostic test that incorporates microbial factors, host factors, and host-microbe interaction might characterize true infection. Assessing volatile organic compounds (VOCs) in exhaled breath may be a useful test for identifying CDI. To identify a wide selection of VOCs in exhaled breath, we used thermal desorption-gas chromatography-mass spectrometry to study breath samples from 17 patients with CDI. Age- and sex-matched patients with diarrhea and negativeC.difficiletesting (no CDI) were used as controls. Of the 65 VOCs tested, 9 were used to build a quadratic discriminant model that showed a final cross-validated accuracy of 74%, a sensitivity of 71%, a specificity of 76%, and a receiver operating characteristic area under the curve of 0.72. If these findings are proven by larger studies, breath VOC analysis may be a helpful adjunctive diagnostic test for CDI.


Subject(s)
Volatile Organic Compounds , Humans , Volatile Organic Compounds/analysis , Breath Tests/methods , Gas Chromatography-Mass Spectrometry , ROC Curve , Diarrhea
16.
Infect Dis (Lond) ; 56(5): 376-383, 2024 May.
Article in English | MEDLINE | ID: mdl-38424673

ABSTRACT

BACKGROUND: Nucleic acid amplification tests (NAAT) are considered the gold standard for COVID-19 diagnosis. These tests require professional manpower and equipment, long processing and swab sampling which is unpleasant to the patients. Several volatile organic compounds (VOCs) have been identified in the breath of COVID-19 patients. Detection of these VOCs using a breath test could help rapidly identify COVID-19 patients. OBJECTIVE: Assess the accuracy of 'Breath of Health' (BOH) COVID-19 Fourier-transform infra-red (FTIR) Spectroscopy-based breath test. METHODS: Breath samples from patients with or without symptoms suggestive for COVID-19 who had NAAT results were collected using Tedlar bags and were blindly analysed using BOH FTIR spectroscopy. BOH Measures several VOCs simultaneously and differentiating positive and negative results. BOH results were compared to NAAT results as gold standard. RESULTS: Breath samples from 531 patients were analysed. The sensitivity of BOH breath test was found to be 79.5% and specificity was 87.2%. Positive predictive value (PPV) was 74.7% and negative predictive value (NPV) 90.0%. Calculated accuracy rate was 84.8% and area under the curve 0.834. Subgroup analysis revealed that the NPV of patients without respiratory symptoms was superior over the NPV of symptomatic patients (94.7% vs 80.7%, P-value < 0.0001) and PPV of patients with respiratory symptoms outranks the PPV of individuals without symptoms (85.3% vs 69.2%, P-value 0.0196). CONCLUSION: We found BOH COVID-19 breath test to be a patient-friendly, rapid, non-invasive diagnostic test with high accuracy rate and NPV that could efficiently rule out COVID-19 especially among individuals with low pre-test probability.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , COVID-19 Testing , Breath Tests/methods , Spectrum Analysis , Sensitivity and Specificity
17.
J Hazard Mater ; 470: 134151, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38554517

ABSTRACT

Ground-level ozone ranks sixth among common air pollutants. It worsens lung diseases like asthma, emphysema, and chronic bronchitis. Despite recent attention from researchers, the link between exhaled breath and ozone-induced injury remains poorly understood. This study aimed to identify novel exhaled biomarkers in ozone-exposed mice using ultra-sensitive photoinduced associative ionization time-of-flight mass spectrometry and machine learning. Distinct ion peaks for acetonitrile (m/z 42, 60, and 78), butyronitrile (m/z 70, 88, and 106), and hydrogen sulfide (m/z 35) were detected. Integration of tissue characteristics, oxidative stress-related mRNA expression, and exhaled breath condensate free-radical analysis enabled a comprehensive exploration of the relationship between ozone-induced biological responses and potential biomarkers. Under similar exposure levels, C57BL/6 mice exhibited pulmonary injury characterized by significant inflammation, oxidative stress, and cardiac damage. Notably, C57BL/6 mice showed free radical signals, indicating a distinct susceptibility profile. Immunodeficient non-obese diabetic Prkdc-/-/Il2rg-/- (NPI) mice exhibited minimal biological responses to pulmonary injury, with little impact on the heart. These findings suggest a divergence in ozone-induced damage pathways in the two mouse types, leading to alterations in exhaled biomarkers. Integrating biomarker discovery with comprehensive biopathological analysis forms a robust foundation for targeted interventions to manage health risks posed by ozone exposure.


Subject(s)
Biomarkers , Breath Tests , Machine Learning , Mice, Inbred C57BL , Ozone , Animals , Ozone/toxicity , Biomarkers/metabolism , Biomarkers/analysis , Male , Oxidative Stress/drug effects , Air Pollutants/toxicity , Air Pollutants/analysis , Mice , Mass Spectrometry , Exhalation , Lung Injury/chemically induced , Lung Injury/metabolism
18.
Rapid Commun Mass Spectrom ; 38(10): e9737, 2024 May 30.
Article in English | MEDLINE | ID: mdl-38533583

ABSTRACT

RATIONALE: Human exhaled breath usually contains unique proteins that may provide clues to characterize individual physiological activities and many diseases. However, the concentration of exhaled proteins in exhaled breath is extremely low and usually does not reach the detection limits of all online breath mass spectrometry instruments. Therefore, developing a new breath sampler for collecting and characterizing exhaled proteins is important. METHODS: In this study, a new mask-based wearable sampler was developed by fixing metal materials into the inner surface of the KN95 mask. Human exhaled proteins could be directly adsorbed onto the metal material while wearing the mask. After sampling, the collected proteins were eluted, digested, and identified using nano-liquid chromatography-tandem mass spectrometry (nano-LC-MS/MS). RESULTS: The adsorption of exhaled proteins was evaluated, showing that modified gold foil is an effective material for collecting exhaled proteins. Various endogenous proteins were successfully identified from exhaled breath, many of which can be potential biomarkers for disease diagnosis. CONCLUSIONS: By coupling the newly developed mask sampler with nano-LC-MS/MS, human exhaled proteins were successfully collected and identified. Our results show that the mask sampler is wearable, simple, and convenient, and the method is noninvasive for investigating disease diagnosis and human health.


Subject(s)
Tandem Mass Spectrometry , Wearable Electronic Devices , Humans , Tandem Mass Spectrometry/methods , Pilot Projects , Breath Tests/methods , Chromatography, Liquid/methods , Aerosols
19.
ACS Sens ; 9(3): 1575-1583, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38483350

ABSTRACT

Monitoring of isoprene in exhaled breath is expected to provide a noninvasive and painless method for dynamic monitoring of physiological and metabolic states during exercise. However, for real-time and portable detection of isoprene, gas sensors have become the best choice for gas detection technology, which are crucial to achieving the goal of anytime, anywhere, human-centered healthcare in the future. Here, we first report a mixed potential type isoprene sensor based on a Gd2Zr2O7 solid electrolyte and a CdSb2O6 sensing electrode, which enables sensitive detection for isoprene with sensitivities of -21.2 mV/ppm and -65.8 mV/decade in the range of 0.05-1 and 1-100 ppm. The sensing behavior of the sensor follows the mixed potential sensing mechanism and was further verified by the electrochemical polarization curves. The significant differentiation between the sensor response to exhaled breath of healthy individuals and simulated breath containing different concentrations of isoprene demonstrates the potential of the sensor for the detection of isoprene in exhaled breath. Simultaneously, monitoring of isoprene during exercise signifies the feasibility of the sensor in dynamic monitoring of physiological indicators, which is not only of great significance for optimizing training and guiding therapeutic exercise intervention in sporting scenarios but also expected to help further reveal the interaction between exercise, muscle, and organ metabolism in medicine.


Subject(s)
Breath Tests , Gases , Hemiterpenes , Humans , Breath Tests/methods , Butadienes , Biomarkers
20.
Nitric Oxide ; 145: 57-59, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38428515

ABSTRACT

Emerging data from clinical studies have shown pro-inflammatory effects associated with e-cigarette use. Fractional exhaled nitric oxide (FeNO) is a biomarker of pulmonary type 2 (T2) inflammation. The effect of chronic e-cigarette use on FeNO is unclear. The aim of this study was to compare FeNO levels in COPD ex-smokers who use e-cigarettes (COPDE + e-cig) to COPDE ex-smokers (COPDE) and COPD current smokers (COPDS). FeNO levels were significantly higher in COPDE + e-cig (median 16.2 ppb) and COPDE (median 18.0 ppb) compared to COPDS (median 7.6 ppb) (p = 0.0003 and p < 0.0001 respectively). There was no difference in FeNO levels between COPDE + e-cig compared to COPDE (p > 0.9). The importance of our results is that electronic cigarette use does not alter the interpretation of FeNO results, and so does not interfere with the use of FeNO as a practical biomarker of T2 inflammation, unlike current cigarette smoking in COPD. Whilst the effect of electronic cigarette use on FeNO levels is not the same as cigarette smoke, this cannot be taken as evidence that electronic cigarettes are harmless. These differential pulmonary effects can be attributed to differences in the chemical composition of the two products.


Subject(s)
Electronic Nicotine Delivery Systems , Pulmonary Disease, Chronic Obstructive , Humans , Nitric Oxide , Breath Tests , Inflammation , Exhalation , Biomarkers
SELECTION OF CITATIONS